Teltonika FMC130 – wiring diagram
Teltonika FMC130 Wiring Diagram
Wiring and electrical connection guide for the Teltonika FMC130 4G GPS Tracker. See the power supply, digital and analog inputs, digital outputs, 1-Wire connection and external LV-CAN connections in detail.
The 12 connections of the FMC130
The FMC130 has a 2×6-pin socket and offers very flexible connection options. The function of each PIN is shown below, according to the device's official pinout.
Power supply and ignition
VCC
Positive power supply of the device. Connect it to a permanent supply of +10 to +30V DC.
GND
Negative pole and ground of the device. Connect it to a reliable ground point on the vehicle.
DIN1
Digital input, usually used for ignition detection.
Digital and analog inputs
DIN2-N / AIN1
Works as negative digital input DIN2 or as analog input AIN1 with a range of 0–30V DC.
DIN3 / AIN2
Can be used as Digital Input 3 or as Analog Input 2 with a measuring range of 0–30V DC.
Digital outputs
DOUT1
Open-collector output for controlling an external relay or another compatible circuit. Maximum load 0.5A DC.
DOUT2
Second open-collector digital output for a relay, buzzer or other compatible external applications.
DOUT3
Third open-collector digital output. Adds the option to remotely control an external circuit.
1-Wire and external connections
1-Wire Power
Power output +3.8V for compatible 1-Wire devices and sensors.
1-Wire Data
Data line for iButton, temperature sensors and other compatible 1-Wire devices.
TX EXT
External TX communication line for connecting a compatible Teltonika LV-CAN.
RX EXT
External RX communication line for receiving data from a compatible Teltonika LV-CAN adapter.
FMC130 power supply
VCC connects to a permanent positive supply and GND to a solid, clean and reliable ground point on the vehicle.
Ignition detection
DIN1 can be connected to a line that carries positive voltage only when the vehicle's ignition switch is in the ON position.
Analog sensors
AIN1 and AIN2 can be used to monitor an analog signal, fuel level or other compatible sensors.
DOUT / Relay control
The digital outputs can be used to drive a relay, buzzer or other compatible circuits through suitable wiring.
iButton and 1-Wire sensors
The 1-Wire connection supports compatible iButtons and sensors, such as temperature sensors.
LV-CAN connection
The TX EXT and RX EXT lines are used to communicate with compatible Teltonika CAN adapters and read vehicle data.
Important before installation
A GPS tracker must be installed in a vehicle's electrical circuit by a qualified auto electrician. Before making any connection, check the voltage and function of each wire with a multimeter. The DOUT outputs are open collector and must not be used to power a large load directly.
| PIN | Name | Type | Function |
|---|---|---|---|
| 1 | VCC | Power supply | Positive supply +10 to +30V DC |
| 2 | DOUT3 | Digital output | Open collector, max 0.5A DC |
| 3 | DIN3 / AIN2 | Configurable input | Digital Input 3 or Analog Input 2, 0–30V |
| 4 | DIN2-N / AIN1 | Configurable input | Negative DIN2 or Analog Input 1, 0–30V |
| 5 | DIN1 | Digital input | Ignition or another positive digital signal |
| 6 | TX EXT | External connection | INPUT 6 / LV-CAN TX |
| 7 | GND | Power supply | Negative pole / vehicle ground |
| 8 | DOUT1 | Digital output | Open collector, max 0.5A DC |
| 9 | DOUT2 | Digital output | Open collector, max 0.5A DC |
| 10 | 1-Wire Power | Power output | +3.8V for 1-Wire devices |
| 11 | 1-Wire Data | Data line | Sensor and iButton data |
| 12 | RX EXT | External connection | INPUT 5 / LV-CAN RX |
Teltonika FMC130 – Installation & wiring
Use the diagram as a technical guide to connect the FMC130 correctly. For special applications, CAN adapters, sensors and relay control, consult Teltonika's official technical documentation or a qualified auto electrician.