Teltonika FMC650 – wiring diagram

TELTONIKA WIRING GUIDE

Teltonika FMC650 Wiring Diagram

Complete electrical connection guide for the Teltonika FMC650 4G GPS Tracker. See the power supply, digital and analog inputs, digital outputs, the two CAN interfaces, the 1-Wire connection and the K-Line in detail.

8–32V DC
4× DIN
4× AIN
4× DOUT
2× CAN
1-Wire
K-Line
Teltonika FMC650 4G LTE GPS Tracker
FMC650 4G LTE Cat 1 · GNSS · Bluetooth · Dual CAN · Professional telematics
FMC650 2×10 PINOUT

The 20 connections of the Teltonika FMC650

The FMC650 has a main 2×10-pin socket with 20 connections in total. The PIN numbers and their functions are listed below, according to Teltonika's official pinout.

Power supply and ignition

1

GND (-)

Ground

Negative pole and ground of the device. Connect it to a reliable ground point or to the battery's negative terminal.

11

VCC (+)

Power Supply

Positive power supply of the FMC650. Connect it to a permanent supply of +8 to +32V DC.

15

DIN1

Dedicated Ignition Input

Digital input 1, specifically designed to detect the vehicle's ignition.

Digital inputs

5

DIN2

Digital Input 2

Second digital input for monitoring an external positive digital signal.

14

DIN3

Digital Input 3

Third digital input for sensors, switches, doors or other compatible applications.

4

DIN4

Digital Input 4

Fourth digital input for an additional external digital signal.

Analog inputs

17

AIN1

Analog Input 1

Analog input 1 with a selectable measuring range of 0–30V or 0–10V DC.

7

AIN2

Analog Input 2

Analog input 2 with a selectable measuring range of 0–30V or 0–10V DC.

10

AIN3

Analog Input 3

Analog input 3 for measuring a compatible 0–30V or 0–10V DC analog signal.

18

DOUT4 / AIN4

Configurable I/O

Configurable connection that works either as digital output DOUT4 or as analog input AIN4 with a 0–30V or 0–10V DC range.

Digital outputs

19

DOUT1

Digital Output 1

Open-collector digital output for driving an external relay or another compatible circuit.

9

DOUT2

Digital Output 2

Second open-collector digital output for a relay, buzzer or another external circuit.

8

DOUT3

Digital Output 3

Third open-collector digital output for remote control of an external application.

18

DOUT4 / AIN4

Configurable I/O

Can be configured as a fourth open-collector digital output or as analog input AIN4.

CAN1 and CAN2 interfaces

2

CAN1L

CAN Low – Channel 1

Low line of the first SAE J1939 CAN bus.

12

CAN1H

CAN High – Channel 1

High line of the first SAE J1939 CAN bus.

6

CAN2L

CAN Low – Channel 2

Low line of the second SAE J1939 CAN bus.

16

CAN2H

CAN High – Channel 2

High line of the second SAE J1939 CAN bus.

1-Wire and K-Line

3

1-Wire Power

Dallas 1-Wire Power

Power output for compatible Dallas 1-Wire devices.

13

1-Wire Data

Dallas 1-Wire Data

Data line for iButton, temperature sensors and other 1-Wire devices.

20

K-Line

Tachograph Interface

K-Line interface for online transfer of vehicle data from a compatible digital tachograph.

FMC650 – Official PINOUT diagram

The image below shows the official layout, numbering and colour coding of the 20 pins of the Teltonika FMC650 2×10 socket.

Teltonika FMC650 official connection diagram and 2x10 pinout

Tap the diagram to view it full size.

Official diagram by Teltonika Telematics

FMC650 power supply

VCC connects to a permanent positive supply and GND to a reliable ground point.

PIN 11 → +8…32V DC
PIN 1 → GND

Ignition detection

DIN1 is the dedicated ignition input of the FMC650 and connects to a real ignition line.

PIN 15 → DIN1 / IGNITION

Analog sensors

The AIN inputs can be used for fuel level and compatible analog sensors.

PIN 17 → AIN1 · PIN 7 → AIN2
PIN 10 → AIN3 · PIN 18 → AIN4

DOUT / Relay control

The DOUT outputs are open collector and can be used with a suitable external relay.

PIN 19 → DOUT1 · PIN 9 → DOUT2
PIN 8 → DOUT3 · PIN 18 → DOUT4

CAN connection

The FMC650 has two independent SAE J1939 CAN channels for commercial vehicles and special applications.

CAN1: PIN 12 H / PIN 2 L
CAN2: PIN 16 H / PIN 6 L

iButton and 1-Wire

The 1-Wire connection supports compatible iButtons and Dallas 1-Wire sensors.

PIN 3 → 1-WIRE POWER
PIN 13 → 1-WIRE DATA
!

Important before installation

The FMC650 must be installed by a qualified auto electrician. Before making any connection, disconnect the power and check the voltage and function of each wire with a multimeter. The DOUT outputs are open collector and must not power large loads directly.

FMC650 quick connection table
PIN Name Type Function
1 GND (-) Power supply Negative pole and device ground
2 CAN1L CAN SAE J1939 CAN Low – channel 1
3 1-Wire Power Power supply Power for Dallas 1-Wire devices
4 DIN4 Digital input Digital Input 4
5 DIN2 Digital input Digital Input 2
6 CAN2L CAN SAE J1939 CAN Low – channel 2
7 AIN2 Analog input Input range 0–30V or 0–10V DC
8 DOUT3 Digital output Open-collector output
9 DOUT2 Digital output Open-collector output
10 AIN3 Analog input Input range 0–30V or 0–10V DC
11 VCC (+) Power supply Positive supply +8 to +32V DC
12 CAN1H CAN SAE J1939 CAN High – channel 1
13 1-Wire Data Data Dallas 1-Wire data line
14 DIN3 Digital input Digital Input 3
15 DIN1 Digital input Dedicated ignition detection input
16 CAN2H CAN SAE J1939 CAN High – channel 2
17 AIN1 Analog input Input range 0–30V or 0–10V DC
18 DOUT4 / AIN4 Configurable I/O Open-collector digital output or analog input
19 DOUT1 Digital output Open-collector output
20 K-Line Tachograph K-Line for online transfer of digital tachograph data

Teltonika FMC650 – Installation and wiring

Use the diagram as a technical guide to connect the FMC650 correctly. For connection to the CAN bus, a digital tachograph, analog sensors, 1-Wire devices or external relays, consult Teltonika's official technical documentation and a qualified auto electrician.