Teltonika FMC130 – wiring diagram

TELTONIKA WIRING GUIDE

Teltonika FMC130 Wiring Diagram

Wiring and electrical connection guide for the Teltonika FMC130 4G GPS Tracker. See the power supply, digital and analog inputs, digital outputs, 1-Wire connection and external LV-CAN connections in detail.

10–30V DC
3× DIN
2× AIN
3× DOUT
1-Wire
Teltonika FMC130 4G GPS Tracker
FMC130 4G LTE Cat 1 · GNSS · Bluetooth · Advanced I/O
FMC130 2×6 PINOUT

The 12 connections of the FMC130

The FMC130 has a 2×6-pin socket and offers very flexible connection options. The function of each PIN is shown below, according to the device's official pinout.

Power supply and ignition

1

VCC

Power Supply

Positive power supply of the device. Connect it to a permanent supply of +10 to +30V DC.

7

GND

Ground

Negative pole and ground of the device. Connect it to a reliable ground point on the vehicle.

5

DIN1

Digital Input 1

Digital input, usually used for ignition detection.

Digital and analog inputs

4

DIN2-N / AIN1

Configurable Input

Works as negative digital input DIN2 or as analog input AIN1 with a range of 0–30V DC.

3

DIN3 / AIN2

Configurable Input

Can be used as Digital Input 3 or as Analog Input 2 with a measuring range of 0–30V DC.

Digital outputs

8

DOUT1

Digital Output 1

Open-collector output for controlling an external relay or another compatible circuit. Maximum load 0.5A DC.

9

DOUT2

Digital Output 2

Second open-collector digital output for a relay, buzzer or other compatible external applications.

2

DOUT3

Digital Output 3

Third open-collector digital output. Adds the option to remotely control an external circuit.

1-Wire and external connections

10

1-Wire Power

+3.8V Output

Power output +3.8V for compatible 1-Wire devices and sensors.

11

1-Wire Data

Data Line

Data line for iButton, temperature sensors and other compatible 1-Wire devices.

6

TX EXT

Input 6 / LV-CAN TX

External TX communication line for connecting a compatible Teltonika LV-CAN.

12

RX EXT

Input 5 / LV-CAN RX

External RX communication line for receiving data from a compatible Teltonika LV-CAN adapter.

FMC130 – Full wiring diagram

The diagram below shows the available connections of the Teltonika FMC130 to the vehicle's electrical system, external relays, sensors and 1-Wire devices.

Teltonika FMC130 full wiring and connection diagram

Tap the diagram to view it full size.

FMC130 power supply

VCC connects to a permanent positive supply and GND to a solid, clean and reliable ground point on the vehicle.

PIN 1 → +10…30V    PIN 7 → GND

Ignition detection

DIN1 can be connected to a line that carries positive voltage only when the vehicle's ignition switch is in the ON position.

PIN 5 → DIN1 / IGNITION

Analog sensors

AIN1 and AIN2 can be used to monitor an analog signal, fuel level or other compatible sensors.

PIN 4 → AIN1    PIN 3 → AIN2

DOUT / Relay control

The digital outputs can be used to drive a relay, buzzer or other compatible circuits through suitable wiring.

PIN 8 → DOUT1 · PIN 9 → DOUT2 · PIN 2 → DOUT3

iButton and 1-Wire sensors

The 1-Wire connection supports compatible iButtons and sensors, such as temperature sensors.

PIN 10 → POWER    PIN 11 → DATA

LV-CAN connection

The TX EXT and RX EXT lines are used to communicate with compatible Teltonika CAN adapters and read vehicle data.

PIN 6 → TX EXT    PIN 12 → RX EXT
!

Important before installation

A GPS tracker must be installed in a vehicle's electrical circuit by a qualified auto electrician. Before making any connection, check the voltage and function of each wire with a multimeter. The DOUT outputs are open collector and must not be used to power a large load directly.

FMC130 quick connection table
PIN Name Type Function
1 VCC Power supply Positive supply +10 to +30V DC
2 DOUT3 Digital output Open collector, max 0.5A DC
3 DIN3 / AIN2 Configurable input Digital Input 3 or Analog Input 2, 0–30V
4 DIN2-N / AIN1 Configurable input Negative DIN2 or Analog Input 1, 0–30V
5 DIN1 Digital input Ignition or another positive digital signal
6 TX EXT External connection INPUT 6 / LV-CAN TX
7 GND Power supply Negative pole / vehicle ground
8 DOUT1 Digital output Open collector, max 0.5A DC
9 DOUT2 Digital output Open collector, max 0.5A DC
10 1-Wire Power Power output +3.8V for 1-Wire devices
11 1-Wire Data Data line Sensor and iButton data
12 RX EXT External connection INPUT 5 / LV-CAN RX

Teltonika FMC130 – Installation & wiring

Use the diagram as a technical guide to connect the FMC130 correctly. For special applications, CAN adapters, sensors and relay control, consult Teltonika's official technical documentation or a qualified auto electrician.